NDT เครื่องวัดความหนาระบบอัลตร้าโซนิค
Ultrasonic Thickness Gauge NOVASCOPE-6000
High precision ultrasonic thickness gage with a substantial amount of adjustable settings and parameters to accomplish most UT thickness measurement applications.
It is the most comprehensive instrument of NDT Systems’ current thickness gage product line.

- Class leading ultra thin spatial resolution
- High-Resolution (0.0001in, 0.0025mm)
- Multi-probe capability
- Touchscreen controls
- 0.0001" (0.0025 mm) digital resolution; as low as 0.010" (0.254 mm) thickness resolution
- Compatible with contact, delay line or immersion transducers
- Dual-Trace display; A-Trace and gates
- Displays English or Metric units
- Velocity display (quartz-stabilized, digital)
- Full RF or rectified RF display
- Selectable multiple echo interval
- Receiver attenuation control plus manual gain and Automatic Gain Control (AGC)
- TAC (Thickness Amplitude Compensation) for noise suppression
- Outputs: Alarms, USB, Serial RS-232C, Micro HDMI
 |
|
 |
|
 |
Single or Dual Element:
Can use both single & dual probes |
|
Alarm mode:
Alarm mode on limits |
|
Variable Units:
Change between mm/ inch |
|
|
|
|
|
 |
|
 |
|
 |
Multi-Probe:
Can use multiple probe types |
|
Data Transfer:
Can be connected to PC |
|
Adjustable Velocity:
Velocity can be adjusted |
|
|
|
|
|
 |
|
 |
|
 |
Benchtop:
Designed for benchtop use |
|
Adjustable Gain:
Gain can be adjusted |
|
Thru Coating mode:
Can measure through coatings |
|
|
|
|
|
 |
|
 |
|
|
High Resolution:
Resolution to 0.0001 inches |
|
Min/Max Mode:
Measures max and min thickness |
|
|
Specification
Dimensional Readout |
|
English and Metric
Gaging Range English: 0.005-10 inches;
Metric 0.13-100 mm (depending upon material) |
Digital Resolution |
English Units |
± 0.0001" on 1" range
± 0.001" on 10" range |
|
Metric Units |
± 0.001 mm on 10 mm range
± 0.01 mm on 100 mm range |
Measuring Mode |
|
Sets mode for contact, delay line or immersion transducers |
Readout Mode |
|
Selects digital display for thickness or velocity |
Pulser |
Risetime |
5 ns |
|
Amplitude |
150, 250, 400 volts
Peak into 50 Ohms |
|
Repetition rate |
625, 1250, 2,500, 5000 Hz |
|
Damping |
15 to 520 Ohms - 1 Ohm increments |
Receiver |
Adjustable gain |
100 dB |
|
Automatic gain control |
100 dB dynamic range |
|
Reject |
Variable threshold to full scale |
Bandwidth |
Bandwidth |
30 MHz (3 dB down) |
Attenuator |
Attenuator |
0, 10, and 20 dB selectable |
A-Trace Display |
Sweep width |
Switchable down to 50 ns/Div
Continuously adjustable |
|
Sweep delay |
1 ms to 80 ms |
|
Display |
Dual Trace; A-Trace plus selectable
Gate Traces (IP, IF, T or TAC) |
|
Display modes |
Full wave RF, positive or negative
Rectified |
T-Gate |
|
Thickness gate with adjustable sync |
T-Gate Start/Stop |
|
Selectable on positive or negative half cycles |
IP-Gate |
|
0.25 to 20 ms (contact), 1.0 to 0 ms (continued) (delay or immersion) |
IF-Gate |
|
0.1 to 8.0 ms |
TAC-Gate |
|
Adjustable thickness amplitude
Compensation of gain
Start control: 0.02 to 6 ms
Amplitude control: 0 to 100 dB
Slope control: 0.1 to 50 ms |
Alarms |
|
Three functions: LO, HI, LO/HI |
Outputs |
|
Alarms, Serial RS-232C, IP Sync and USB |
Inputs |
|
External sync |
Power Source |
Power Source |
Battery & AC |
Power Consumption |
|
50 Watts |
Warranty |
|
One year |
Screenshots