2-Zone Cold and Hot Shock Test Chamber TII-Series
ห้องทดสอบอุณหภูมิเปลี่ยนแปลงอย่างรวดเร็วแบบ 2 โซน
ขนาดภายในสามารถปรับแต่งได้ตามความต้องการของลูกค้า
ล็อคแบบก้านเฉพาะ
เทอร์มินัลควบคุมพลังงานสำหรับตัวอย่าง
รูนำสายไฟเปิดด้านบน
การป้องกันความร้อนสูงเกินอิสระสามจุด
ตัวควบคุมพัฒนาขึ้นอย่างอิสระโดย Topect

2-Zone Cold and Hot Shock Test Chamber
Inner dimensions can be customized as required by the client
Unique lever lock
Power supply control terminal of sample
Top opening lead hole
Triple independent over-temperature protection
Controller developed independently by Topect
Technical Specifications
Model |
TⅡ100-
40W
|
TⅡ200-
40W
|
TⅡ300-
40W
|
TⅡ100-
55W
|
TⅡ200-
55W
|
TⅡ300-
55W
|
TⅡ100-
65W
|
TⅡ200-
65W
|
TⅡ300-
65W
|
Internal Volume (L) |
100 |
200 |
300 |
100 |
200 |
300 |
100 |
200 |
300 |
Inner Dimension (mm) |
W |
650 |
650 |
970 |
650 |
650 |
970 |
650 |
650 |
970 |
H |
460 |
460 |
460 |
460 |
460 |
460 |
460 |
460 |
460 |
D |
370 |
670 |
670 |
370 |
670 |
670 |
370 |
670 |
670 |
Outer Dimension (mm) |
W |
1660 |
1660 |
1980 |
1660 |
1660 |
1980 |
1660 |
1660 |
1980 |
H |
2050 |
2050 |
2050 |
2050 |
2050 |
2050 |
2050 |
2050 |
2050 |
D |
2100 |
2400 |
2400 |
2100 |
2400 |
2400 |
2100 |
2400 |
2400 |
Sample Weight (kg) |
7.8 |
7.8 |
7.8 |
7.8 |
7.8 |
7.8 |
7.8 |
7.8 |
7.8 |
Testing Method |
Hanging basket of the sample zone goes up or down |
Preheating and Pre-cooling Temperature |
Preheating: (60~185)℃ Pre-cooling: (-80~5)℃ |
Temperature Recovery a/Switch Time |
Recovery time: 2~5min Switch time: ≤10s |
Temperature Deviation (℃) |
±2.0℃ |
Exposure Time |
High-temperature exposure: 30min Low-temperature exposure: 30min |
Weight (kg) |
1090 |
1480 |
1550 |
2000 |
1100 |
1510 |
1580 |
1170 |
1590 |
Maximum Current (A) |
46 |
60 |
65 |
110 |
51 |
65 |
65 |
58 |
96 |
Power (kW) |
30 |
37 |
40 |
76 |
32 |
40 |
40 |
37 |
60 |
Circulating Cooling Water (t/h) |
5 |
8 |
8 |
15 |
5 |
10 |
10 |
9 |
13 |
Material |
Inner Chamber |
SUS304Stainless steel sheet SS304 |
Outer Chamber |
Two-sided galvanved plafe- with the surface treated
by electrostatic powder coating
|
Thermal Insulation |
High-temperature Glass wool/Rockwool & PU foam |
Actuator |
High-temperature Tank |
Heater: nickel-chrome electric heater wire |
High-temperature shock fan; axial flow fan for preheating |
Low-temperature Tank |
Heater: nickel-chrome electric heater wire;
regenerator: slice aluminum plate
|
Fan: Low-temperature resistance fan |
Damper Driver |
Pneumatic cylinder: For driving the cylinder to move up and down |
Air supply |
Refrigeration System |
Refrigeration mode: Low-noise piston type compressor
& binary cascade refrigeration
|
Refrigerant: Environmental protection refrigerant R404A, R23 |
Controller
System |
Screen & PLC |
7.0" or 10.0", 800×480 resolution, mixed output PLC |
Running Mode |
Program mode |
Setting Mode |
Simplified Chinese & English, input by touch |
Program Capacity |
groups of programs, each consisting of 3 sections
for setting 32000 times of cycles. The program has link function.
|
Setting Range |
Adjusted by ±5.0℃ according to the according to the
maximum range of the equipment
|
Display Resolution |
Temperature: 0.1℃; time: s |
Sensor |
PT100 (platinum resistor) |
Control Mode |
Low-temperature cold balance & anti-integral saturation PID & auto-tuning |
Curve Record |
With automatic data storage function.
User can browse the data by sliding on the screen; screen shot function is available.
|
Additional Function |
Fault alarm, cause and handling method:
Timed startup/stop; power failure protection, user permission function
|
Communication Function |
Support RS485, LAN (internet port), GPRS (phone) and other communication modes, which enable users to conduct remote monitoring simply.
Data acquisition: IBM PC compatible machine.
CPU above PII, memory above 128M, operating system in Simplified Chinese / English.
|
Data Acquisition |
1. With USB interface, curve data of three months can be saved, and historical curve and test data can be downloaded.
2. It can be an alternative to the recorder. With built-in extra memory, 3 months of data under the condition that the machine runs for 24 hours continuously can be saved. The sampling time is 1min. It can replace computer storage. Users can export historical data through USB disk (time is optional) and generate files in the format of CSV.
3. Connect to PC (optional) - Record testing data through computer monitoring software. It can display the curve. PC can be used as remote terminal to realize remote monitoring. |
Compressed Air |
Pressure: 0.5~0.7MPa Flow: 0.1m3/min |
Circulating Cooling Water |
Water pressure: 0.25~0.4MPa Water temperature: ≤30℃ |
Power Supply (V)/(Hz) |
AC voltage 380V±38V Frequency 50Hz±0.5Hz 3-phase 4-wire & earthing protection |
Standard Configuration |
1Testing hole of Φ50; 1 sets of sample holders; 4 casters |
Safety Device |
Leakage switch, motor, compressor, phase sequence, over-temperature protection, dry-burn protection, etc. |
a Recovery condition: Room temperature +25℃ The sample is plastic encapsulated integrated circuit (uniformly distributed).
Note: Shock series test chamber can be customized according to client’s requirements. |
Shock Series Product Features
- Customizable observation window based on customer needs.
- Utilizes a 2-box method to reduce temperature recovery time of samples.
- Features a cylinder-controlled steady “up and down movement method” for the test basket.
- High airspeed and consistent sample temperature promote uniform temperature distribution within the chamber.
- Inner chamber constructed from SS304 stainless steel; outer chamber made from CRCS with electrostatic powder coating.
- Modular refrigerator, waterway, and electrical control systems for enhanced safety and maintenance ease.
- Air vents are positioned at a 45° angle in the chamber to ensure temperature uniformity; allows faster stabilization of temperature and humidity, with adjustable guide vanes for improved consistency inside the chamber.
Refrigeration System
● Major parts and accessories from internationally acclaimed brands.
● Refrigerant R404A and R23 are used in the system with the ozone depletion factor of 0.
● All condensers are installed with filtration device, which ensures long-term reliable operation of the unit
● Intelligent control of refrigeration system optimises power consumption.
● Imported compressor: Copeland, Bock or Bitzer, low in noise, stable in operation and powerful in performance.
● Before welding, all pipelines are charged with nitrogen to protect the interior of the copper part from oxidation.The weld joints are sprayed with varnish for protection.
● Refrigeration unit adopts modular production, including sub-assembly, part assembly and general assembly; standardized modules are convenient to install, debug and maintain.
(1)(2)(3)(4)(5)
T Ⅱ 70-40 W
|
(1)
|
T
|
Marine Series
|
(2)
|
T
|
II:2-chamber type
III: 3-chamber type
|
(3)
|
70
|
Internal volume(L)
|
(4)
|
40
|
Minimum shock negative temperature (℃)
|
(5)
|
W
|
W:Water cooling type
A:Air cooling type
|
Control System
●Topect touch-type temperature and humidity controller is specially developed by Topect for the industry of environmental equipment; it consists of touch screen, PLC, temperature module and humidity module. The touch screen is equipped with visual editing software, PLC logic programmer, extendable I&O port and extendable multi-point temperature; USB interface allows users to export monthly/weekly data.Remote monitoring is realized through RS485 communication and PC connection.

●The high-performance controllers are developed independently by TOPECT, characterized by 65536 color 7", TFT true-color touch screen and 800×480 dot matrix, it ensures real effects and easy in operation.In addition, the entire interface is concise and clear, convenient and reliable.

●Our controllers have powerful debugging protection function, fault alarm and troubleshooting description; extendable I&O port can be used to input different control programs according to requirement to realize different functions; they can be customized as per requirement.

●With PLC program control, this system has timed running & stop function and power failure protection function to improve stability of the system.
●It can be connected to a centralized monitoring software and supports communication protocol, it is convenient for users to develop the program once again; multiple test chambers can be monitored remotely.
Standard Configuration and Optional Accessories
●Power supply control terminal for test samples.
●Overpressure & overheating protection device for compressor.
●Cable port hole of φ50
●Stainless steel inner chamber and external chamber coated with TOPECT standard color.
●Self-diagnosis function alarm is used to identify and assist in solving the problem.
●Exhaust pressure regulating device (used for preventing overpressure when the compressor runs).
●Condensation pressure regulating device(water cooling type device used to adapt to different winter and summer environment).
●Door seal strip with unique thermal insulation function and testing holes are equipped to reduce condensation and frosting.
●Over-temperature protection is installed for the air regulation channel (over-temperature protection 2).
●Overload and short circuit protection.
●Overheating protection of circulating fan.
●Sound and light alarm and prompt function.
●Auto tuning function of temperature controller.
●Phase sequence and phase failure protection device of general power supply
●Adjustable over-temperature protection device (over-temperature protection 1).
●Over-temperature control is provided in the controller(over-temperature protection 2).
●Screen locking function of controller.
●Low pressure protection device for cooling water supply(Inlet).
Optional Accessories
●Temperature recorder(fig.1).
●Communication port and software for remote control and data transmission(fig.2).
●Observation window (fig.3).
●Lead hole of different specifications can be provided as per customer requirement(φ50,φ80,φ100,φ160,etc.).
●Super long time frost frcc.
●Movable temperature sensor.
●Customize the sample cart according to users'needs.
●Equipment is customized as per requirement.