3nh,Benchtop Spectrophotometer,YS6003
YS6003 desktop spectrophotometer can accurately measure and express various color difference formulas and color indexes in a variety of color spaces. The built-in temperature sensor monitors and compensates the test environment to ensure more accurate measurement results. It is widely used in reflection samples, transparent samples color transfer and quality control in plastic electronics, paint and ink, textile and garment printing, printing and other industries.
Features
● High configuration of hardware: 7 inches TFT Color Capacitive Touch-screen Display; Bluetooth 2.1; Concave Grating.
● Double Array 256 Image Element CMOS Sensor; Long life-span stable xenon lamp.
● With reflective and transmissive spectrum, accurate Lab value, good to calculate color formula and do precise color transmission.
● Auto identify measuring aperture. Freely switchable between 3 measuring apertures: Φ 25.4mm/8mm/4mm.
● Built-in temperature sensor to monitor and compensate the measuring temperature to ensure the measurement more precision.
● Wavelength range 360nm – 780nm.It can be used to test fluorescent samples with wide applicability and simple operation
● Independent light source detector to ensure the light source reliable.
● Multiple accessories, sample holders, fixation clamp, suitable to more working condition.
● Big capacity data storage, for 20000 pieces test result.
● Built-in camera locating.
● More powerful extended functions at the PC software.
TECHNICAL SPECIFICATIONS
Model: YS6003
Optical Geometry: Reflect: di:8°(diffused illumination, 8-degree viewing angle); SCI (specular component included); SCE (specular component excluded); Include UV / excluded UV light source; Transmittance: di:0°, e:0° (diffuse illumination: 0° viewing); SCI (specular component included); Haze(ASTM D1003); Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN 5033 Teil7
Application: It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.
Integrating Sphere Size: Ø154mm
Light Source: 360 nm to 780 nm, Combined LED Light (5 million life span)
Spectrophotometric Mode: Concave Grating
Sensor: 256 Image Element Double Array CMOS Image Sensor
Wavelength Range: 360-780nm
Wavelength Interval: 10nm
Semibold Width: 10nm
Measured Reflectance Range: 0 - 200%
Measuring Aperture: Reflective: Ø30mm/Ø25.4mm, Ø10mm/Ø8mm, Ø6mm/Ø4mm; Transmissive: Ø30mm/Ø25mm; Remark:
1. Automatic identification of switch caliber.
2. Customized Configuration caliber and lens position
Specular Component: Reflectance: SCI&SEC / Transmittance: SCI&SEC
Color Space: CIE LAB, XYZ, xyY, LCh, CIE LUV, Munsell, s-RGB, HunterLab, xy, DIN Lab99
Color Difference Formula: ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00, ΔIN99, ΔE*99 (Hunter)
Other Colorimetric Index: WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), T (ASTM E313, CIE/ISO), M (Metamerism Index), Staining Resistance, Color Fastness, Color Strength, Opacity, Δg Glossiness, Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003)
Observer Angle: 2°/10°
Initial: D65, A,C,D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12
Displayed Data: Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset
Measuring Time: About 2.4s (Measure SCI & SEC about 5s)
Repeatability: Spectral Reflectance: Ø25.4mm/SCI, Standard deviation within ΔE*ab 0.06% (400 nm to 700 nm: within 0.05%); Chromaticity value: Ø25.4mm/SCI, Standard deviation within ΔE*ab 0.01 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration); Spectral Transmittance: Ø25.4mm/SCI, Standard deviation within 0.06% (400 nm to 700 nm: within 0.06%); Chromaticity value: Ø25.4mm/SCI, Standard deviation within ΔE*ab 0.015 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration).
Inter-instrument Error: Ø25.4mm/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles)
Dimension: L*W*H=370x300x200mm
Weight: Approx. 9.6kg
Power: AC 24V, 3A, Power adapter power supply
Illuminant Life Span: 5 years, more than 3 million times measurements
Display: 7-inch TFT color LCD, Capacitive Touch Screen
Data Port: USB & Printer serial port
Data Storage: Standard 1000 Pcs, Sample 20000 Pcs
Language: Simplified Chinese, Traditional Chinese, English
Operating Environment: 0~40°C, 0~85%RH (no condensing), Altitude <2000m
Storage Environment: 20~50°C, 0~85%RH (no condensing)
Standard Accessory: Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black sample, Sample holder, 25.4 caliber, 8 caliber, 4 caliber
Optional Accessory: Micro-printer, Transmissive Test Component, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components