เครื่องทดสอบเฉดสี DS-700-C Series Spectrophotometer (CHN) เครื่องทดสอบเฉดสี DS-700-C Series Spectrophotometer (CHN)

The DS-700C series is based on the 45/0 ring lighting optical structure design. The innovative ring lighting system eliminates direction dependence and minimizes the impact of texture.
Repeatability accuracy can reach: dE*ab≤0.02
The difference between stations can reach: dE*ab≤0.2
Provides 30+ measurement parameters and 40 evaluation light sources
12 calibers provided to suit different applications
Provides functions such as camera framing and positioning, UV measurement, mobile phone measurement, and color matching software.

Innovative 45/0 ring illumination optical system eliminates direction dependence
The innovative 45/0 ring lighting system eliminates directional dependence and minimizes the impact of textures. Measurements on matte, textured and structured surfaces bring great advantages, such as automotive interiors, clothing, plastics, coatings, etc. The innovative 45/0 ring lighting system is closer to the color vision of the measured object.

Provide professional color density measurement function
The instrument has measurement indicators such as color density, total density, dot area, dot area increase, overprint, printing contrast, hue error and grayscale. It is widely used in ink printing, film processing, textile printing and dyeing, plastic electronics and other industries for accurate color measurement and Quality control, especially suitable for precise measurement and quality control of optical density, dot increase and other indicators in ink printing.

Excellent inter-stage consistency, dE*ab≤0.2
Excellent technology and craftsmanship ensure that the DS-700C series has excellent inter-stage consistency. The BCRA series of standard color tiles are used for color transmission and color value traceability, ensuring that instruments of the same model maintain excellent inter-stage differences between upstream and downstream companies.

Ultra-high repeatability accuracy: dE*ab≤0.02
Repeatability accuracy is an important indicator to describe the accuracy of a spectrophotometer/spectrophotometer.
The excellent photoelectric test system solution ensures that the repeatability accuracy of the DS-700C series spectrophotometer/spectrophotometer is unmatched by similar products.
The repeatability evaluation of the DS-700C series spectrophotometer/spectrophotometric densitometer adopts strict standards and shows excellent repeatability accuracy.

More than 30 measurement parameters and nearly 40 evaluation light sources
DS-700C series spectrophotometer/spectrochromatic density meter provides 30+ measurement indicators such as spectral reflectance, CIE-Lab, CIE-LCh, ΔE*ab, hiding power, whiteness, yellowness, etc.; A, B, C , D50, D55, D65 and other nearly 40 evaluation light sources are available, covering almost all color measurement indicators and light source types in the industry.

Supports 12 test calibers
In order to facilitate users to measure samples of different sizes, the DS700C spectrophotometer supports 12 calibers for customers to use. Stable type: Φ11mm+Φ10mm+Φ6mm+Φ5mm+Φ3mm+Φ1*3mm, smart type: ▽11mm+▽10mm+▽6mm+ ▽5mm+▽3mm+▽1*3mm, can be flexibly applied to various usage and testing conditions.

Long-term stability of the instrument
Compared with existing products, the DS-700C series spectrophotometer/spectrophotometric density meter does not require frequent manual calibration when used. As long as it is placed on the calibration base, the instrument will automatically perform overall instrument functions and calibration based on its own status and environmental factors. Accurate calibration ensures that the instrument is always in a stable state and ready for use at any time.
The white plate in the calibration base is the baseline for the instrument's accuracy. Through long-term investment and research, Color Spectrum has integrated zirconium material, known as "artificial diamond", as a calibration whiteboard, with a surface Mohs hardness of 9. Because the material itself has a hardness and stability comparable to diamonds, it is guaranteed that the surface of the calibration whiteboard will not be scratched and will not change color with changes in temperature and humidity. Compared with similar foreign and domestic products, which use ordinary industrial ceramics or even plastics as calibration whiteboards, the stability and durability are further improved, ensuring the performance of the instrument.

ColorExpert
The DS-700C series spectrophotometer/fengaun comes with the Windows color management system ColorExpert, which can be connected to the DS-700 series spectrophotometer via Bluetooth or USB cable. ColorExpert is a full-featured color management software with four major functional modules: My Color, Color Detection, Color Matching System, and Personal Center.
model |
|
|
|
Measurement structure※
|
45/0
|
Measurement Repeatability ※ ※
|
ΔE*ab≤ 0.025 |
ΔE*ab≤ 0.02
|
ΔE*ab≤ 0.02
|
Difference between stages ※ ※ ※
|
ΔE*ab≤0.25
|
ΔE*ab≤0.25
|
ΔE*ab≤0.2
|
Display accuracy
|
0.01
|
Measuring diameter
|
There are 4 stable and smart types in total:
Φ11mm, Φ10mm
|
There are 8 stable and smart types in total:
Φ11mm, Φ6mm, Φ3mm, 1*3mm
▽11mm, ▽6mm, ▽3mm, ▽1*3mm
|
There are 12 stable and smart types in total:
Φ11mm, Φ10mm, Φ6mm,
Φ5mm, Φ3mm, 1*3mm
▽11mm, ▽10mm, ▽6mm,
▽5mm, ▽3mm, ▽1*3mm
|
measurement standard
|
Spectral reflectance, CIE-Lab, CIE-LCh, HunterLab, CIE-Luv, XYZ, Yxy, RGB, color difference (ΔE*ab, ΔE*cmc, ΔE*94, ΔE*00),
Whiteness (ASTM E313-00, ASTM E313-73, CIE, ISO2470/R457, AATCC,
Hunter, Taube Berger Stensby), Yellowness (ASTM D1925,
ASTM E313-00, ASTM E313-73), blackness (My, dM), stain fastness,
color fastness, Tint (ASTM E313-00),
Color density CMYK (A, T, E, M), metamerism index Milm, Munsell,
hiding power, strength (dye strength, tinting power)
|
Light source conditions
|
A,B,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,
U30,U35,DLF,NBF,TL83,
TL84,ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-
BH1,LED-RGB1,LED-V1,LED-V2
|
Printing quality indicators |
Color density CMYK(A,T,E,M) |
Color density CMYK (A, T, E, M), dot area, dot area increase, overprint rate,
printing contrast, grayscale, hue error
|
lighting source
|
Full-band balanced LED light source |
Full-band balanced LED light source + UV |
|
|
|
CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7
|
|
|
|
Dual column high-precision CMOS array sensor
|
|
|
|
|
Reflectivity measurement range
|
|
|
0.01%
|
measurement observation method
|
|
|
Intelligent automatic calibration
|
|
Andriod, iOS, Windows, WeChat applet
|
|
Guarantee first-level measurement qualification
|
measure time
|
about 2 seconds
|
about 1 second |
interface
|
USB, Bluetooth
|
Screen
|
Full color screen, 3.5 inches
|
battery capacity
|
Can continuously measure 8000 times on a single charge, 7.2V/3000mAh
|
Light source life
|
1 million times in 10 years
|
language
|
Simplified Chinese, English
|
storage
|
Instrument: 100 standards and 10,000 samples; APP: Mass storage
|
※45 degree ring lighting/0 degree angle reception
※※After whiteboard calibration, measure the standard deviation of the whiteboard 30 times at 5-second intervals.
※※※Measurement average of 12 color plates of BCRA series II
|