เครื่องทดสอบแรงดึง แรงกด KJ-1100 เครื่องทดสอบแรงดึง แรงกด KJ-1100
Use environment ◆ Working environment temperature :20±15℃(adhesive industry 23±2); ◆ Humidity of working environment: below 80%(65%±5%), no condensation; ◆ If the voltage of power supply does not exceed ±10% of the rated voltage, in order to ensure the normal use of the product and ensure the accuracy of the test, it is recommended to install a steady voltage power supply before using this product; ◆ A product shall be installed horizontally on a solid basis, and the level shall be better than 0.2 mm/1000mm;. ◆ After the correct installation of the product, the surrounding surface should be not less than 0.7 m of space; ◆ Use of this product is prohibited in the presence of corrosive gases, vibrations and magnetic fields.
Directly enter the test interface after startup
Button response in test interface: Button "up" : control the machine up action; Button "down" : control the machine down action; Button "Test" : perform the test; Button "Stop" : Click this button to stop the operation of the machine in the process of ascending and descending, and click this button to end the test in the process of testing; Button "zero" : the force, maximum force, displacement, deformation equivalent to zero; Button "return" : make the machine return to the position when the "return to zero" button was pressed last time, press the "stop" button to stop the machine at any time during the return process, and press the "return" button again to continue the return; You can also press the "return to zero" button to stop the machine, but press the "return to zero" button to stop the machine, and then press the "return to zero" button to stop the machine, and the "return to zero" button will stop the machine. Button "Delete All" : delete all data; Button "Delete" : delete the selected data; Button "Point fetching interface" : enter the point fetching result interface. In the test, this button is the point fetching interface button, and at the end of the test, it is the point fetching interface button. Button "Manual control" : open the touch control and lifting speed setting panel, as shown below:
Displacement sensor
Rubber extensometer (large deformation)
[Technical parameters] Warning: It is strictly forbidden to test beyond the rated load of the sensor, otherwise the sensor will be completely damaged!
|
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |